sieobex/tests
2026-10-01 02:46:52 -05:00
..
cli.cx70.test.ts Initial slop 2026-09-19 13:04:16 -05:00
cli.device.test.ts Initial slop 2026-09-19 13:04:16 -05:00
cli.el71.test.ts Initial slop 2026-09-19 13:04:16 -05:00
cli.s75.test.ts Initial slop 2026-09-19 13:04:16 -05:00
cliSuite.ts Switch to node-sie-serial from NPM 2026-10-01 02:46:52 -05:00
device.ts Switch to node-sie-serial from NPM 2026-10-01 02:46:52 -05:00
emulator.ts Switch to node-sie-serial from NPM 2026-10-01 02:46:52 -05:00
globalSetup.ts Initial slop 2026-09-19 13:04:16 -05:00
README.md Switch to node-sie-serial from NPM 2026-10-01 02:46:52 -05:00
target.ts Switch to node-sie-serial from NPM 2026-10-01 02:46:52 -05:00

End-to-end tests

These drive the built CLI as a subprocess against Siemens phones. By default the phone is real firmware running under pmb887x-emu, so every listing, transfer and delete goes through the phone's own AT interpreter and FlexMem OBEX server, over a serial link QEMU exposes as a TCP chardev.

pnpm test:e2e

The same suite runs against a phone on a cable, which is the only way to cover a real link and a real flash:

SIEOBEX_E2E_DEVICE=/dev/ttyUSB0 pnpm test:e2e:device

cliSuite(target) is what both share. A PhoneTarget (target.ts) is either an emulator the suite boots, with its model and directories known from the table in emulator.ts, or the phone on the other end of SIEOBEX_E2E_DEVICE, which is whatever someone plugged in.

Against a real phone

Variable Default What it is
SIEOBEX_E2E_DEVICE — the port, e.g. /dev/ttyUSB0; without it the suite skips
SIEOBEX_E2E_DIR /Data/Misc a directory the tests may write into
SIEOBEX_E2E_SMALL_FILES_DIR / a directory to list
SIEOBEX_E2E_RECONNECT_WAIT_MS 5000 the pause before connecting again
SIEOBEX_E2E_READY_TIMEOUT_MS 45000 how long to keep trying the first connect
SIEOBEX_E2E_BAUDRATE — pin the handshake speed instead of probing
SIEOBEX_E2E_BAUDRATES 115200,57600,19200 the speeds to run a session at, one each; empty skips
SIEOBEX_E2E_VERBOSE — 1 logs every CLI command and how long it took

It writes to the phone. Inside SIEOBEX_E2E_DIR it creates sieobex-e2e.bin and a sieobex-tree folder, reads them back, and deletes them again. It touches nothing else and never writes outside that directory, but it is a real file system: point it somewhere of no consequence. SIEOBEX_E2E_DIR has to name a directory below the root, and the root itself is refused.

The default for SIEOBEX_E2E_DIR suits SGOLD and NewSGOLD phones. An EGOLD phone needs one of its own folders instead: a C60 lists a Data in its root but refuses to enter it (setpath to "Data" failed: Forbidden), and keeps Sounds, Pictures, Java, Animations, tmp and the rest directly in the root. Before any test runs, the suite lists the directory and pushes a 32 byte file into it, so the wrong one fails in a second with the phone's own answer and a listing of its root, rather than eight tests later.

Baud rates

Two of the tests are about the link speed itself. One pins a session to each rate in SIEOBEX_E2E_BAUDRATES and reads the phone at it; the other gives connect no speed at all and checks the probe settles on one of the five it walks (115200, 57600, 19200, 230400, 9600) and that the session works.

They are only fully meaningful on a cable. QEMU exposes the emulated phone as a TCP chardev and ignores the host speed — the firmware programs USART0 itself — so against an emulator these show the option reaching the port and coming back in status, not the wire changing speed. Each rate costs a session, so the emulators only do two and a hardware run can be trimmed with the variable.

Knowing what it is doing

A real phone spends seconds where an emulator spends milliseconds, so the suite narrates itself: each phase is a [device +elapsed] line, and any single CLI command taking more than three seconds is named as it finishes. SIEOBEX_E2E_VERBOSE=1 names every command instead.

[/dev/ttyUSB0 +0.0s] starting the phone
[/dev/ttyUSB0 +0.0s] connecting
[/dev/ttyUSB0 +0.9s] connected in 0.9s: SIEMENS C60 v26 (EGOLD, max packet 474 bytes)
[/dev/ttyUSB0 +1.1s] checking /Sounds is a directory the tests may write into
[/dev/ttyUSB0 +2.4s] ready

A connect that fails is retried until SIEOBEX_E2E_READY_TIMEOUT_MS, each attempt naming the phone's own error. The emulators keep the old three minutes, because they are still booting; a real phone is either on the cable or it is not, so 45 seconds is enough to say so.

Two things the suite cannot know about a phone it did not boot: the model and the platform. Rather than assert them it reads them out of status, checks the phone identified itself as something on a known platform, and prints what it found. The listing default is the root because it is the one directory that every phone has and that is never empty — the writable one is empty again as soon as the suite has cleaned up after itself. Point SIEOBEX_E2E_SMALL_FILES_DIR at a folder of real files to exercise the sizes and dates in the long listing too.

Nothing else changes: the same nineteen tests run, the daemon still gets a private SIEOBEX_HOME, and a failure leaves the phone disconnected rather than mid-session.

What the emulated ones need

Piece Default location Override
pmb887x-emu binary tests/.emu/pmb887x-emu OBEX_E2E_EMU
Fullflash images tests/fullflashes/ OBEX_E2E_FULLFLASHES
An X server started automatically DISPLAY

Both default paths are gitignored, so a symlink into an emulator build and a fullflash collection elsewhere is the intended setup. These are the same variable names and defaults node-sie-serial uses, so one setup serves both repositories.

A phone whose fullflash is missing skips its suite with the reason rather than failing, since a checkout without the images is the normal case.

QEMU opens a GTK window even with nothing to show it, so globalSetup.ts starts one Xvfb for the run unless DISPLAY is already set.

Why the emulated ones are slow

Each emulator test file boots one phone and the tests inside it share that session. A boot is tens of seconds, and the file system behind OBEX comes up well after the AT interpreter does, so the suite waits for a real file operation to succeed rather than for a fixed time.

The suite runs with --no-file-parallelism on purpose: QEMU drives the phone on a precise instruction clock tied to real time, so two emulators competing for CPU boot more slowly than the tests are willing to wait.

Phone Platform Notes
EL71 NewSGOLD ~8 KiB OBEX packets, fast link
S75 NewSGOLD same generation, different layout
CX70 SGOLD 1030 byte packets and a 19200 baud link, so roughly 35 times slower; it is the one that exercises the multi-packet paths

The test payload is 1024 bytes for that reason: large enough to cross the CX70's packet limit, small enough to move over its link quickly.

Keep the payloads small for another reason too. The emulated USART hands the guest its input far faster than a real wire would, so a bulk upload arrives as an interrupt storm, the firmware misses a GSM deadline and panics on purpose. An unpatched emulator dies on the first few-hundred-byte write; a patched one is only known to survive writes of a few kilobytes. A push of a hundred kilobytes will kill the phone and every later command times out. That is an emulator limit, not a sieobex or phone limit, and it is why the suite does not test large transfers. node-sie-serial/tests/README.md has the details.

Reconnecting costs a pause

The last three tests of each suite cover -d, which means taking the session down and bringing it back up. OBEX.disconnect()'s +++ escape really does hand the wire back to the AT interpreter, but the phone needs a few seconds before the next handshake catches it, and connecting too early does not just fail that attempt: it loses the session for the rest of the boot, and every later connect answers Phone not found at every baud rate. That is what PhoneTarget.reconnectWaitMS is for — 5 s on the x75 phones, 20 s on the CX70, the same values the library's own suite uses, and 5 s for a real phone unless SIEOBEX_E2E_RECONNECT_WAIT_MS says otherwise.

Most of what looked like a phone needing minutes was the daemon closing the port on top of its own +++ escape; with that fixed a real phone reconnects immediately, and a phone that was left in OBEX mode anyway is escaped out of it by the next connect.

Nothing in the CLI hides this. A user who disconnects a phone and immediately names it with -d again can hit it too, which the main README says.

Isolation

Every CLI subprocess gets SIEOBEX_HOME pointing at a private temporary directory, so a daemon started by the tests can never collide with one the developer is using, and nothing is left in ~/.sieobex.

The fullflash is always copied before use and the emulator runs with --rw: writes really land in the flash image and persist, so the shared images must not be the ones a phone writes into.

The CX70 is opt-in

SIEOBEX_E2E_CX70=1 pnpm test:e2e

It goes quiet for roughly twenty seconds at a time, which is longer than the client's fifteen second protocol timeout, so whatever was in flight fails with OBEX response timeout, and a session that loses one exchange usually loses the rest. How often it happens depends on how busy the host is, because QEMU ties the phone's clock to real time. On the machine this was written on, the EL71 and the S75 passed every run and the CX70 lost between two and nine tests each time, so leaving it in the default run would mean a suite that is red for reasons that have nothing to do with the code.

It is still worth running deliberately: it is the only SGOLD phone, the only one with a 1030 byte packet limit, and the only one on a 19200 baud link, so it covers the multi-packet paths the others do not. The library's own CX70 suite sees the same stalls and carries one permanently failing test for a related quirk.

Nothing in the CLI papers over this: recovering a stalled session is the library's job, and a real phone does not behave this way.

When a phone stops answering

A firmware panic shows up as a pile of timeouts in the tests and nothing else. The emulator prints >>EXIT<< over the serial line in that case, and the suite dumps the emulator output when it sees it. sieobex log inside a failing run, or connect --debug all, shows the protocol traffic.