.id 0xF024C010, 0xF024C021
.type MODULE
.size 0x100000
.name ADC
.qemu pmb887x-adc
.descr Measurement Interface and Analog Control
.irq INT0
.irq INT1
CLC 0x00
*MOD_CLC
ID 0x08
*MOD_ID
ANA_CTRL 0x14 Analog Control Register
RXREF_PU 0 1 RX Local Reference Buffer Switch
BG_PWUP 1 1 Band-Gap Power Control
PA_OFF1 2 1 PAOUT1 Analog Offset Correction
NONE=0
MINUS_50MV=1
TX_DIS 4 1 Disable Analog Part of Modulator Unit
TXREF_PU 8 1 TX Local Reference Buffer Switch
PAOPM1 14 1 PAOUT1 Output Buffer Operation Mode
STANDARD=0
ENHANCED=1
PA_CAL1 16 6 PAOUT1 Digital Offset Correction
TREF 28 4 Common Mode Voltage for Baseband TX Path
0_955V=0 0000 – 0.955 V (default, typical)
1_010V=1 0001 – 1.010 V
1_065V=2 0010 – 1.065 V
1_120V=3 0011 – 1.120 V
1_175V=4 0100 – 1.175 V
1_230V=5 0101 – 1.230 V
1_285V=6 0110 – 1.285 V
1_340V=7 0111 – 1.340 V
0_900V=15 1111 – 0.900 V (typical)
CTRL 0x18 Measurement Control Register
MX 0 6 Measurement mode
OFF=0
M0=1
M1=2
M2=3
M7=8
M8=9
M9=10
M10=11
M0_M9_A=12
M0_M9_B=18
INV 6 1 Inversion of Pre-Amplifier Input
CSEL 11 1 Fast Settling of Pre-Amplifier
TC 12 3 Current Source for Current Measurement Mode
OFF=0 Voltage mode
I_30=1 Current mode 30uA
I_60=2 Current mode 60uA
I_90=3 Current mode 90uA
I_120=4 Current mode 120uA
I_150=5 Current mode 150uA
I_180=6 Current mode 180uA
I_210=7 Current mode 210uA
FREQ 16 3 ADC Sampling Rate Control
SINGLE_SHOT=0 Single conversion (default)
DIV_640=1
DIV_320=2
DIV_160=3
DIV_80=4
DIV_40=5
DIV_20=6
DIV_15=7
BUFSIZE 19 3 Size of Output Buffer
1=0 MEAS_DATA0
2=1 MEAS_DATA0..1
3=2 MEAS_DATA0..2
4=3 MEAS_DATA0..3
5=4 MEAS_DATA0..4
6=5 MEAS_DATA0..5
7=6 MEAS_DATA0..6
8=7 MEAS_DATA0..7
MXREF 22 4 Reference Measurement Mode
OFF=0
M0=1
M1=2
M2=3
M7=8
M8=9
M9=10
M10=11
M0_M9_A=12
M0_M9_B=18
ENSTOP 27 1 Circular Output Buffer Disable
ENTRIG 28 1 Triggered Mode Enable
ADCON 29 1 ADC Power Save Control
START 31 1 Start Conversion
STAT 0x1C Measurement Status Register
WPTR 0 3 Write Pointer – Index of latest valid MEAS_DATAx written
BUSY 30 1 ADC Busy Flag
READY 31 1 Data Ready Flag
DATA 0x20-0x3C 4 Measurement Data Register
CLK 0x40 Measurement Peripheral Clock Control Register
K 0 8 Numerator of Fractional Divider
L 8 8 Denominator of Fractional Divider
SRC 0xF0-0xF4 4
*MOD_SRC