mirror of
https://github.com/siemens-mobile-hacks/pmb887x-dev.git
synced 2026-11-26 02:47:30 +00:00
109 lines
2.4 KiB
INI
109 lines
2.4 KiB
INI
.id 0xF024C010, 0xF024C021
|
||
.type MODULE
|
||
.size 0x100000
|
||
.name ADC
|
||
.qemu pmb887x-adc
|
||
.descr Measurement Interface and Analog Control
|
||
|
||
.irq INT0
|
||
.irq INT1
|
||
|
||
CLC 0x00
|
||
*MOD_CLC
|
||
|
||
ID 0x08
|
||
*MOD_ID
|
||
|
||
ANA_CTRL 0x14 Analog Control Register
|
||
RXREF_PU 0 1 RX Local Reference Buffer Switch
|
||
BG_PWUP 1 1 Band-Gap Power Control
|
||
PA_OFF1 2 1 PAOUT1 Analog Offset Correction
|
||
NONE=0
|
||
MINUS_50MV=1
|
||
TX_DIS 4 1 Disable Analog Part of Modulator Unit
|
||
TXREF_PU 8 1 TX Local Reference Buffer Switch
|
||
PAOPM1 14 1 PAOUT1 Output Buffer Operation Mode
|
||
STANDARD=0
|
||
ENHANCED=1
|
||
PA_CAL1 16 6 PAOUT1 Digital Offset Correction
|
||
TREF 28 4 Common Mode Voltage for Baseband TX Path
|
||
0_955V=0 0000 – 0.955 V (default, typical)
|
||
1_010V=1 0001 – 1.010 V
|
||
1_065V=2 0010 – 1.065 V
|
||
1_120V=3 0011 – 1.120 V
|
||
1_175V=4 0100 – 1.175 V
|
||
1_230V=5 0101 – 1.230 V
|
||
1_285V=6 0110 – 1.285 V
|
||
1_340V=7 0111 – 1.340 V
|
||
0_900V=15 1111 – 0.900 V (typical)
|
||
|
||
CTRL 0x18 Measurement Control Register
|
||
MX 0 6 Measurement mode
|
||
OFF=0
|
||
M0=1
|
||
M1=2
|
||
M2=3
|
||
M7=8
|
||
M8=9
|
||
M9=10
|
||
M10=11
|
||
M0_M9_A=12
|
||
M0_M9_B=18
|
||
INV 6 1 Inversion of Pre-Amplifier Input
|
||
CSEL 11 1 Fast Settling of Pre-Amplifier
|
||
TC 12 3 Current Source for Current Measurement Mode
|
||
OFF=0 Voltage mode
|
||
I_30=1 Current mode 30uA
|
||
I_60=2 Current mode 60uA
|
||
I_90=3 Current mode 90uA
|
||
I_120=4 Current mode 120uA
|
||
I_150=5 Current mode 150uA
|
||
I_180=6 Current mode 180uA
|
||
I_210=7 Current mode 210uA
|
||
FREQ 16 3 ADC Sampling Rate Control
|
||
SINGLE_SHOT=0 Single conversion (default)
|
||
DIV_640=1
|
||
DIV_320=2
|
||
DIV_160=3
|
||
DIV_80=4
|
||
DIV_40=5
|
||
DIV_20=6
|
||
DIV_15=7
|
||
BUFSIZE 19 3 Size of Output Buffer
|
||
1=0 MEAS_DATA0
|
||
2=1 MEAS_DATA0..1
|
||
3=2 MEAS_DATA0..2
|
||
4=3 MEAS_DATA0..3
|
||
5=4 MEAS_DATA0..4
|
||
6=5 MEAS_DATA0..5
|
||
7=6 MEAS_DATA0..6
|
||
8=7 MEAS_DATA0..7
|
||
MXREF 22 4 Reference Measurement Mode
|
||
OFF=0
|
||
M0=1
|
||
M1=2
|
||
M2=3
|
||
M7=8
|
||
M8=9
|
||
M9=10
|
||
M10=11
|
||
M0_M9_A=12
|
||
M0_M9_B=18
|
||
ENSTOP 27 1 Circular Output Buffer Disable
|
||
ENTRIG 28 1 Triggered Mode Enable
|
||
ADCON 29 1 ADC Power Save Control
|
||
START 31 1 Start Conversion
|
||
|
||
STAT 0x1C Measurement Status Register
|
||
WPTR 0 3 Write Pointer – Index of latest valid MEAS_DATAx written
|
||
BUSY 30 1 ADC Busy Flag
|
||
READY 31 1 Data Ready Flag
|
||
|
||
DATA 0x20-0x3C 4 Measurement Data Register
|
||
|
||
CLK 0x40 Measurement Peripheral Clock Control Register
|
||
K 0 8 Numerator of Fractional Divider
|
||
L 8 8 Denominator of Fractional Divider
|
||
|
||
SRC 0xF0-0xF4 4
|
||
*MOD_SRC
|