c166-ghidra-module/data/patterns/C166_patterns.xml
2026-08-08 22:58:40 +03:00

22 lines
837 B
XML

<patternlist>
<!--
Conservative TASKING-style function starts. A candidate must follow a
return and begin with either three saved registers or two saved registers
plus a stack allocation. Shorter prologues are deliberately omitted:
their byte patterns occur too often in C166 data tables.
-->
<patternpairs totalbits="32" postbits="16">
<prepatterns>
<data>0xcb 0x00</data> <!-- ret -->
<data>0xdb 0x00</data> <!-- rets -->
<data>0xfb 0x88</data> <!-- reti -->
</prepatterns>
<postpatterns>
<data>0x88 ....0000 0x88 ....0000 0x88 ....0000</data>
<data>0x88 ....0000 0x88 ....0000 0x26 0xf0 ........ ........</data>
<align mark="0" bits="1"/>
<funcstart validcode="6" validcodemax="20" contiguous="true"/>
</postpatterns>
</patternpairs>
</patternlist>